Skip to content

Evominiv T

0÷10V compact temperature transmitter
This device can be a reliable alternative to common assemblies with connection head. Then moulded connector allow easy installation

SKU: EVOMINIVatT Category:

Need Help?

Get in touch with
Sales Team

Sales Team

enquiry@italcoppie.com

+39 0372 441220

We will get back to you within 2 business days

Electrical technical data
Power supply
20 ÷28 Vcc (polarity protected)
Accuracy (*)
(*) @25°C
maximum value between ±0.2 °C and ±0.2% of range set
Temperature influence (*)
(*) deviation from 20°C
maximum value between ±0.15 °C/ 25 °C and ±0.15% of range
Permitted load
10 Kohm
Sensor failure signalling
upscale (> 10,5 V) action
downscale (0 V) action
Sensor short circuit signalling
fixed to downscale (0 V) action
Factory default
ranges available:
0 ÷ 100 °C
0 ÷ 150 °C
0 ÷ 300 °C
-50 ÷ 150 °C
Range (-50 ÷ 100) °C
-50 ÷ 50 °C
Other configurations on request
Effect of power supply
Negligible
Electronic board operating temperature
-40 ÷80°C
EMC
According to EN 61326-1:2013
Sensing element operating temperature range
-50 ÷110°C
Sensing element
Pt1000 Ω @ 0°C
Accuracy class in accordance to IEC751 (*)
(*) The accuracy class is valid only in the temperature range indicated by the norm
cl. A
Sheath diameter d
(*) test in water in accordance with IEC 751. Time taken to reach 63.2% of temperature step
Ø 3,5 tapered conic to Ø 3 mm
Response time < 3,5 seconds(*)
Sheet material
AISI 316
Insulation resistance
100 M Ω@ 100 Vdc.
Stem length L
13 mm
24 mm
Type of connector
male 4-pin connector with M12x1 metal screw lock (in accordance with IEC 61076-2-101 STANDARDS)
Connection body material
THERMOPLASTIC
Process connection (*)
(*) Thread STANDARDS (CYL. GAS in accordance with UNI-ISO 228) (CON. GAS in accordance with UNI-ISO 7-1) (NPT in accordance with ANSI B 1.20.1)
1/8″ GAS CIL. sec. UNI-ISO 228
1/8″ NPT
1/4″ NPT
Maximum working pressure
PN 40 BAR
Marking
Stating production batch, pin-out and power supply range
International protection marking (*)
(*) According to IEC 60529
IP65/67