Skip to content

2-Wire Thermoplastic Rubber Probe

Airtight 2 wire double insulation rubber probe
-Pt100, Pt1000, thermistor (NTC) sensing element
-IP-68 tightness degree
-Suitable for long-time immersion in corrosive liquids
-Available with a stainless steel case

SKU: IKE2 Category:

Need Help?

Get in touch with
Sales Team

Sales Team

enquiry@italcoppie.com

+39 0372 441220

We will get back to you within 2 business days

Sensing element
Pt100 Ω @ 0°C
Pt1000 Ω @ 0°C
NTC R(25°C)=10Kohm ±1%, beta(25/85)=3977
NTC R(25°C)=10Kohm ±1%, beta(25/85)=3435
NTC R(25°C)=10Kohm ±3%, beta(25/85)=3977
NTC R(25°C)=2.7Kohm ±1%, beta(25/85)=3977
NTC R(25°C)=10Kohm, Beta (25/85) =3969, tol ±0.2°C (0-70°C)
Sensing Element configuration
single 2-wire
Accuracy class in accordance to IEC751 (*)
(*) The accuracy class is valid only in the temperature range indicated by the norm
cl. A
cl. B
Sensing element operating temperature range
-40 ÷105°C
Insulation resistance
100 M Ω@ 1000 Vdc.
Dielectric strength
3750 Vac
Plastic bulb dimension
Ø 5 x20 mm
Plastic bulb material
TPE (MOULDED)
Extension cable
TPE 2 conductors
Cable lenghts E= (subject to feasibility check)
500 mm ÷100 m
Protective sheath
(*) test in water in accordance with IEC 751. Time taken to reach 63.2% of temperature step
missing
Response time < 10 seconds(*)
Ø 6 x L=30 mm
Sheet material INOX
Response time < 15 seconds(*)
Ø 6 x L=40 mm
Sheet material INOX
Response time < 15 seconds(*)
Ø 6 x L=50 mm
Response time < 15 seconds(*)
Sheet material INOX
Ø 6 x L=60 mm
Sheet material INOX
Response time < 15 seconds(*)
Ø 6 x L=70 mm
Sheet material INOX
Response time < 15 seconds(*)
Ø 6 x L=100 mm
Response time < 15 seconds(*)
Sheet material INOX
Ø 6 x L=150 mm
Sheet material INOX
Response time < 15 seconds(*)
Ø 6 x L=200 mm
Sheet material INOX
Response time < 15 seconds(*)
Product marking
marked with production date and traceability code (FOR CONSTRUCTION WITH STAINLESS STEEL TUBE ONLY)
International protection marking (*)
(*) According to IEC 60529
IP68
EXTENSION CABLE
Cable conductors
copper tinned
Number of cable conductors
2
Conductor dimension
AWG 24
Conductor feature
strand (7 wire)
Primary insulation
PP (polypropylene)
Outside diameter of single conductor (*)
(*) primary insulation
about Ø 1.05 mm
Primary insulation colour
1 white, 1 black
Secondary insulation
TPE (thermoplastic rubber) 87 shore A
Secondary insulation colour
black
Cable size or external shape
about Ø 3,3 mm
Cable working temperature
-40 ÷105°C (6h @150°C)
Note
twisted conductors
Sheath length L
Not indicated
Sheath diameter d
Not indicated