TCEPAJ

-wide variety of available diameters and lengths
-transition T° MAX 120°C
-different types of insulation of extension cable
-sensing part for T° over 600°C

SKU: TCEPAJ Category:

Need Help?

Get in touch with

Jacopo Baronio

Jacopo Baronio

enquiry@italcoppie.com

+39 0372 441220

We will get back to you within 2 business days

Thermocouple calibration
type J (iron-constantan)
Sheet material
AISI 304
Sensing part maximum working temperature
600°C
Number of elements (T/C) (*)
(*) Number Elements (T/C) asterisco
double
single
Hot measuring joint
grounded
insulated
Accuracy class in accordance with IEC 584
2 (STANDARD)
1 (SPECIAL)
Sheath diameter d
Ø 1.5 mm
Ø 2 mm
Ø 3 mm
Ø 4.5 mm
M.I.C. min. bending radius
3 times the outer diameter
Insulation resistance
100 M Ω@ 100 Vdc.
Realizable sheat lenghts L= (subject to feasibility check)
50 mm ÷50 m
Transition sleeve diameter
Ø 8 mm
Transition sleeve type
MOULDED Ø 8 x 25 mm
Transition sleeve length
25 mm
Transition sleeve material
POLYAMIDE (OVERMOULDED)
Maximum transition temperature
120°C
Fixing system
bare stem
Compensated cable
silicon; type J DIN
Working temperature -40 ÷ 180°C
silicone; type J IEC
Working temperature -40 ÷ 180°C
silicone; 4 wire type J IEC
Working temperature -40 ÷ 180°C
Cable lenghts E= (subject to feasibility check)
500 mm ÷50 m